911 Carrera S Cabriolet (997) F6-3.8L (2007)
Information
^
The bleeding process is completed more quickly if the canister is positioned at the same height as the coolant reservoir.
5. Push the filler hose of the vacuum pressure gauge -5- onto the canister connection. Draw off the return line -6- of the Venturi nozzle into a second
empty container.
Special canister filling tool
Information
^
A hissing sound after connecting the compressed air supply is normal.
6. Connect the compressed air supply to the Venturi nozzle.
Compressed air supply on Venturi nozzle
7. Open both shut-off valves on the vacuum pressure gauge until the transparent filler hose has completely filled with coolant.
Shut-off valves open
8. Close left shut-off valve on the vacuum pressure gauge and allow a vacuum to build up in the coolant circuit.