porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Diagnosis of Lambda Sensor Downstream Catalyst|Page 1944 > < Diagnosis of Lambda Sensor Downstream Catalyst|Page 1942
Page 1
background image

Oxygen Sensor: Testing and Inspection
Diagnosis Of Universal Lambda Sensor - UEGO

Diagnosis Of Universal Lambda Sensor - UEGO (911 Turbo)

General Description

Offset

Incorrect lambda measurement due to shunting effects. Diagnosis: Lambda-offset of downstream control exceeds threshold.

Heater Coupling

Low impedance coupling between heater and sensor can cause lambda modulations with the heater pulse rate.

Dynamics - Slow Response

Due to aging the sensor dynamics can decrease. Diagnosis: Comparison of measured and estimated (model-based) lambda-error caused by artificial
lambda modulation.

Plausibility

a. Power Stage - Diagnosis:

Output Voltage of the Power Stage will be switched to >= 4.775 Volts, if a hardware malfunction has been detected by IC.

b. UEGO (Universal Lambda Sensor = LSU) not active:

Diagnosis: Lambda(LSU) is close to 1.0, but downstream sensor indicates lean or rich mixture

c. Sensor current high (Lambda LSU lean):

Lambda(LSU) > 1.2 while downstream sensor indicates rich mixture

d. Sensor current low (Lambda LSU rich):

Lambda(LSU) <  0.8 while downstream sensor indicates lean mixture

Oxygen Sensor Output Voltage Characteristic Diagram

Monitoring Overview Diagram

Diagnosis of Lambda Sensor Downstream Catalyst|Page 1944 > < Diagnosis of Lambda Sensor Downstream Catalyst|Page 1942