911 Turbo Cabriolet (996) F6-3.6L Turbo (2004)
Open circuit - short to ground / voltage short / version; vehicle parameters / counter
Frequency counter
When a fault first occurs, a fault entry with the status 'present' is set in the fault memory and the counter is
simultaneously set to '50'.
If a fault is present, the counter is incremented by one whenever the system is 'booted'. The maximum count is 255.
The counter is decremented if the status 'fault no longer present' is entered and the fault does not occur again when
the system is 'booted'. The entry in the fault memory is erased automatically when the counter reaches 0. If the
error occurs again when the counter is between 1 and 49, the counter is reset to 50.
Lock status of MOST ring
The value indicates the status of the MOST ring when the fault occurred:
-
lock
-
unlock
Supply voltage fault type
The display shows which fault type has occurred:
-
no fault type
-
not present
Supply voltage
The value indicates the voltage at the time the fault occurred.
Country-Specific Tuner Settings
Country-specific tuner settings
The following country-specific tuner settings can be coded:
-
Europe
-
North America
-
South America
-
Australia
-
Asia
-
South Africa
-
Japan
General Information on the Fault Memory
General information on the fault memory
Fault code setting conditions
Fault codes can be set in several circumstances, e.g.:
-
Battery disconnected.
-
Plug connections disconnected.
-
Power failure.
In these situations, no fault is present in the system and the fault memory must be erased.
Fault memory Info key [F8]
In order to be able to assess the fault exactly, the fault memory Info key [F8] must be pressed. This information should be saved using the Save key [F4]
and printed out. If a fault code is stored with the status "not present" and no other problems are present, then the fault memory must be erased.
Fault type - Frequency counter/Temperature/Voltage; Speed/Time of occurrence.
Fault type
The display shows which fault type has occurred:
-
No GPS info.
-
Gyroscope faulty.
Frequency counter:
When a fault first occurs, a fault entry with the status 'present' is set in the fault memory and the counter is
simultaneously set to '50'. The counter is incremented by one in the event of an error each time the system is
'booted'. The maximum count is 255.
The counter is decremented if the status 'fault no longer present' is entered and the fault does not occur again when
the system is 'booted'. The entry in the fault memory is erased automatically when the counter reaches 0. If the
error occurs again when the counter is between 1 and 49, the counter is reset to 50.
First occurrence (month, day):
The date (month and day) on which the fault was first detected is displayed.