porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 4382 > < Initial Inspection and Diagnostic Overview|Page 4380
Page 3
background image

In these circumstances, no fault is present in the system and the fault memory must be erased.

Fault memory Info key F8

In order to be able to assess the fault exactly, the fault memory Info key F8 must be pressed. This information should be saved using the Save key F4 and
printed out. If a fault code is stored with "not present" status and no other problems are present, then the fault memory must be erased.

Open circuit - short to ground / voltage short / version; vehicle parameters / counter

Below short to ground limit value:

There is (present) or was (not present) a short circuit to ground or an open circuit in the circuit to the control
module terminal.

Voltage short:

There is (present) or was (not present) a short circuit to voltage.

Checking

Renewed check of fault memory - information after the ignition is switched off and subsequently switched on
again. If the fault memory has been remedied, the text changes from present to not present

Total mileage

Kilometer reading under which the fault has been saved

Vehicle speed

The value indicates the vehicle speed at the time the fault occurred.

Version / vehicle parameters:

Incorrect vehicle coding or coding not yet carried out.

Counter:

When a fault first occurs, a fault entry is made in the fault memory and the counter is simultaneously set to
50.

If a fault is present, the counter is incremented by 1 each time the ignition is switched on. The maximum
count is 100.

The counter is decremented if the fault is no longer present. The fault memory is erased automatically when
the counter reaches 0.

Instrument Cluster Diagnosis - System K22, K23, K27

Control Module Function

Events

NOTE:
-

The occurrence of particular system errors is stored in the event memory. Furthermore, it is possible to read out the time of the occurrence by
means of the [F8] key. The time is shown in minutes. The events stored in the event memory concern components of the instrument cluster and
also components of other control modules like PSM or DME. The following system errors are stored in the event memory:

-

During diagnosis, the events ABS failure and PSM failure are entered into the event memory via communication with the Porsche System Tester II
No. 9588 and the respective warning lights are activated during the automatic control module search. In this case, no fault is present and the event
memory is to be erased after completion of the diagnosis.