Page 1
background image

Fuel Pressure: Testing and Inspection
Connecting and Bleeding Pressure Gauge

CHECKING PRESSURE 

Note:  For better understanding we have numbered connections and lever positions of change-over valve in the following text.

Connecting and Bleeding Pressure Gauge 

1.  Remove air cleaner.

2.  Remove line from mixture control unit to control pressure regulator at control pressure regulator. Connect selector valve into line as shown

(connection 1 to control pressure regulator. Connection 3 to regulator feed line).

3.  Switch selector valve position 2. Let pressure gauge hang down (by its hose), disconnect 2-pole plug at mixture control unit (arrow) and turn on

ignition (fuel pump runs). Move change-over valve lever to position 3 about 5 times at intervals of 10 seconds.

Connecting and Bleeding Pressure Gauge|Page 1650 > < Fuel Pressure|Specifications