porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3306 > < Initial Inspection and Diagnostic Overview|Page 3304
Page 23
background image

Menu item

-

Time zone

Function

Using this menu item, you can code the required time zone.

-

Connect and start the Porsche System Tester II 9588 and switch on the ignition.

-

Select 911 Turbo (996) in the Vehicle type menu and confirm with the >> key.

-

Select PCM2 in the Control units selection menu and confirm with the >> key.

-

Select PCM2 MMI in the 911 Turbo (996) PCM2 function selection menu and confirm with the >> key.

-

Select Coding in the PCM2-MMI function selection menu and confirm with the >> key.

-

Select Time zone in the PCM2 MMI Coding menu and confirm with the >> key.

-

Select the Time zone corresponding to the country of registration using the > key and code with the F8 key.

Vehicle Hand-Over

Vehicle Hand-over

The PCM2 is converted to delivery mode (low-current mode) in production. As known from other systems (alarm system, instrument cluster, roll-over
bar), the PCM2 must be activated with the Porsche System Tester II 9588.

1. Connect and start the Porsche System Tester II 9588 and switch on the ignition.
2.Select the menu item Special functions and press the >> key.
3. Select the menu item Vehicle hand-over and press the >> key.
4. Follow the instructions of the Porsche System Tester II 9588.

Country-specific tuner settings

The following country-specific tuner settings can be coded:

-

Europe.

-

North America.

-

South America.

-

Australia.

-

Asia.

-

South Africa.

-

Japan.

Coding country-specific tuner settings

1. Connect and start the Porsche System Tester II 9588 and switch on the ignition.
2. Select 911 Turbo (996) in the Vehicle type menu and confirm with the >> key.
3. Select PCM2 in the control modules selection and confirm with the >> key.
4. Select PCM2 MMI in the PCM2 function selection and confirm with the >> key.
5. Select Coding in the PCM2 MMI function selection and confirm with the >> key.
6. Select Tuner parameters in the PCM2 MMI coding function selection and confirm with the >> key.
7. Take the country-specific code as it appears in the table, enter it in the form and code with the F8 key.

Coding PCM2

1. Connect and start the Porsche System Tester II 9588 and switch on the ignition.
2. Select 911 Turbo (996) in the Vehicle type menu and confirm with the >> key.
3. Select PCM2 in the control modules selection and confirm with the >> key.
4. Select PCM2 MMI in the PCM2 function selection and confirm with the >> key.
5. Select Coding in the PCM2 MMI function selection and confirm with the >> key.
6. Select PCM2 code in the PCM2 GW coding and confirm with the >> key.
7. Take the PCM2 code from IPAS , enter it in the form and code with the F8 key.

Production mode

If the MOST control module is set to Production mode on, it is in low-current mode. The display remains black, the control module cannot function.

1. Connect and start the Porsche System Tester II 9588 and switch on the ignition.
2. Select 911 Turbo (996) in the Vehicle type menu and confirm with the >> key.
3. Select PCM2 in the control modules selection and confirm with the >> key.
4. Select PCM2 GW in the control modules selection and confirm with the >> key.
5. Select Coding in the PCM2 GW function selection and confirm with the >> key.
6. Select Production mode in the PCM2 GW coding and confirm with the >> key.
7. Select Production mode off menu and code with the F8 key.

Initial Inspection and Diagnostic Overview|Page 3306 > < Initial Inspection and Diagnostic Overview|Page 3304