Page 2
background image

Procedure when the engine is standing still:

4. Connect the Porsche Tester PST 2 in the vehicle, switch on the ignition and switch off all loads, such as the radio and air conditioning.
5. Activate fuel pump relay using Porsche System Tester. To do this, select the line drive links in the DME control unit individual search and then

select fuel pump relay. Activate by pressing the F8 key.

6. Read value on pressure gauge.

Target test values when engine not running: 3.8 ± 0.2 bar.

7. Switch off the fuel pump relay on the System Tester by pressing F8.
8. Switch off ignition, pull off System Tester connecting lead in the vehicle and switch off System Tester.

Checking while engine is idling.

9. To check the engine while it is idling, connect the pressure gauge as described above and start the engine. Switch off the engine after reading the 

fuel pressure.
Target test values when engine is idling: 3.3 ± 0.2 bar.

10. Loosen the union nuts of the connecting cable 9559 for the special tool pressure gauge P 378a on the test connection and remove special tool.

Collect emerging fuel, e.g. with a cloth.

11. Position new closure cap on test connection and tighten (a/f 13 mm).

Tightening torque of new brass closure cap: 2.5 ± 0.5 Nm ( 0.5 ftlb.)

Air Cleaner Housing > < Fuel Pressure|Specifications|Page 585