porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Air Door Cable, HVAC > < Ventilation|Page 4795
Page 2
background image

2. Swivel drive motor to the side and disengage the deflection lever.
3. Disconnect electrical plug connection and detach bracket from the drive motor.

INSTALLATION

1. Ensure that the deflection levers are seated correctly.
2. Tighten fastening screws carefully (plastic housing).
3. Engage electrical plug connections and route wire carefully.
4. Perform function test after installation of the drive motors.

Drive Motor, Fresh Air/Recirculation Valve

Removing and installing drive motor for fresh-air/recirculation valve

Removing and installing drive motor on the installed heating/air-conditioning unit

Removal

1. The recirculation button must be pressed before removal (fresh-air supply blocked). The drive motor can be removed from the installed

heating/air-conditioning unit in this position (recirculation).

2. Remove footwell and right air guide. Disconnect electrical plug connection of the drive motor and undo fastening screw.

3. Disengage pivot pin on the adjusting lever with a screwdriver.
4. Swivel down the drive motor and remove it to the side.

Note:
If the rotary knob for air distribution is set to Defrost (windscreen) with the recirculation button switched on, the recirculation button is automatically
switched off.

Installation

1. The removal or installation position of the drive motor and fresh-air/recirculation valve cannot be changed.
2. Ensure that the deflection lever of the outside air valve is seated correctly.
3. Tighten fastening screw carefully (plastic housing).
4. Engage electrical plug connection and route wire carefully.
5. Perform a function test after installation.

Air Door Cable, HVAC > < Ventilation|Page 4795