porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Customer Safety Information|Page 4279 > < Customer Safety Information|Page 4277
Page 2
background image

^

The temperature of the battery acid must be at least 10°C.

The specific gravity of electrolyte must be checked in all battery cells as follows:

1. Switch ignition off and remove ignition key.

2. Unscrew all battery plugs (plugs of the battery cell).

3. Dip into the battery cell using the acid siphon or the pipette and take up the battery acid.

4. Read off the specific gravity of electrolyte in kg/dm3 on the scale of the battery acid tester and compare with the table shown.

The specific gravity of electrolyte must be at least 1.24 kg/dm3.

-

If the specific gravity of electrolyte is too low, charge battery.

-

After charging the battery, repeat the specific gravity of electrolyte test.

The measuring values for the specific gravity of electrolyte of the individual battery cells should not deviate by more than 0.03 kg/dm3 from each
other.

Example 1: The specific gravity of electrolyte in cell 4 is too low.

Example 2: The specific gravity of electrolyte in cells 4 and 5 is too low. The specific gravity of electrolyte deviations between the battery cells is
larger than 0.03 kg/dm3.

-

If the nominal values are not achieved, replace battery.

-

If the nominal values are achieved, screw in the original plug again.

Open-circuit voltage measurement 

Note!  Use a hand-held multimeter to measure the battery voltage.

1. Switch ignition off and remove ignition key.

2. Disconnect ground strap on the battery.

Note!  After charging and a waiting time of at least 2 hours during which the battery should neither be burdened or charged.