porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Procedures|Page 2004 > < Procedures|Page 2002
Page 3
background image

-

Prior to disconnecting the control module, switch off the ignition and remove the ignition key.

NOTE:

-

If a new DME control module is to be installed in a vehicle, the DME code specified in IPAS and the immobiliser code must be entered in the
DME control module.

-

The codes are available from IPAS or via the importer.

-

Follow the instructions on the Tester.

-

Later versions of the software may display slightly different text or require a slightly different procedure. The instructions you receive from the
tester itself take precedence over this description.

-

During programming, the electric radiator fans may start.

-

Depending on the software version of the PIWIS Tester, a new DME control module can be interrogated for the "old DME programming code". In
this case, enter the code from IPAS which is also used for the "new DME programming code".

-

In some countries (currently USA, Canada) the Ready status must be obtained following a test drive or by using the Porsche System Tester after
the DME control module has been programmed. If in doubt about this, contact the relevant importer.

1. Connect the PIWIS Tester 9718 to the vehicle and start the System Tester. Switch on ignition. Press ">>" to continue.
2. Select vehicle type. Press ">>" to continue.

Read out vehicle data.

3. Switch to the Special functions menu and perform the vehicle handover using the "F8" key.
4. In the Special functions menu, erase All fault memories by pressing ">>".
5. Carry out automatic search of control units.
6. Select DME with the cursor keys and press the ">>" key.
7. Select Program control unit with the cursor keys and press the ">>" key.
8. Select Program control module with the cursor keys and press the ">>" key. Observe the information displayed by the Tester.
9. Enter Vehicle Ident. No., ">>" confirm with "F7".

10. Enter the DME programming code (IPAS), ">>" confirm with "F7".
11. Enter the new immobiliser code (IPAS), ">>" confirm with "F7".
12. Specify vehicle type ">>".
13. Specify transmission type ">>".
14. Specify exhaust standard ">>".
15. Start Programming with "F8". The data and programming status is then loaded on to the DME control module. Do not interrupt the programming

sequence. Observe Tester instructions.

16. For the learning and adaptation routine of the throttle valve (electronic throttle), switch the ignition off, remove ignition key, insert ignition key

and switch on ignition for at least 40 seconds without starting the engine. Do not actuate accelerator pedal. This completes the adaptation of the
throttle adjusting unit and the programming sequence is complete.

17. In the DME menu go to Coding, code Cruise control present, not present.
18. Go to Vehicle data and, if necessary, enter the vehicle-specific data.
19. Read out the fault memories of all control units and delete the DME control module fault on every control unit connected to the CAN.
20. Start engine.
21. Carry out a test drive and read out fault memory again.

Programming DME control module

WARNING:  Sudden voltage interruption of the power supply to the control module.

-

Destruction of the control module.
-

During programming, it is essential to guarantee the power supply for the Porsche System tester. It is essential to connect a battery charger
with a current rating of at least 40 A to the vehicle battery.

-

Prior to disconnecting the control module, switch off the ignition and remove the ignition key.

NOTE:

-

If a new DME control module is to be installed in a vehicle, the DME code specified in IPAS and the immobiliser code must be entered in the
DME control module.

-

The codes are available from IPAS or via the importer.

-

Follow the instructions on the Tester.

-

Later versions of the software may display slightly different text or require a slightly different procedure. The instructions you receive from the
tester itself take precedence over this description.

-

During programming, the electric radiator fans may start.

-

If a DME control module from a different vehicle with ME 7.8 is being used, proceed as follows. As a check, the immobiliser code of the vehicle
in which the control module is being installed (NEW) and of the vehicle from which the control module has been removed (OLD) is required.

-

In some countries (currently USA, Canada) the Ready status must be obtained following a test drive or by using the Porsche System Tester after
the DME control module has been programmed. If in doubt about this, contact the relevant importer.

1. Connect the PIWIS Tester 9718 to the vehicle and start the System Tester. Switch on ignition. Press ">>" to continue.
2. Select vehicle type. Press ">>" to continue.
3. Read out vehicle data.
4. Carry out automatic search of control units.

Procedures|Page 2004 > < Procedures|Page 2002