5. Slide spring band clamp -4- using circlip pliers for spring band clamps, Cayenne hose connections NR.72-1 onto the connection -Arrow A- and
align with the marking on the hose.
6. Relieve the spring band clamp -4--Arrows C- and secure the hose.
7. Push lower hose onto connection 2 of directional-control valve -Arrow B- and align to marking.
8. Slide spring band clamp -3- using circlip pliers for spring band clamps, Cayenne hose connections NR.72-1 onto connection 2 of
directional-control valve -Arrow B- and align with the marking on the hose.
9. Relieve the spring band clamp -3--Arrow C- and secure the hose.
10. Push upper hose onto connection 3 of directional-control valve -Arrow A- and align to marking.
11. Slide spring band clamp -2- using circlip pliers for spring band clamps, Cayenne hose connections NR.72-1 onto connection 2 of
directional-control valve -Arrow A- and align with the marking on the hose.
12. Relieve the spring band clamp -2--Arrows B- and secure the hose.
13. Push the hose onto the water line -Arrow A-.
14. Slide spring band clamp -1- using circlip pliers for spring band clamps, Cayenne hose connections NR.72-1 onto connection 2 of
directional-control valve -Arrow B- and align with the marking on the line.
15. Relieve the spring band clamp -1--Arrows C- and secure the hose.
16. Push on connector -Arrow A- until the locking tab -B- is felt to engage.