4. Remove air filter cover with suction hose.

ATTENTION:
Risk of damaging the fastening bolts.
-

The fastening bolts will break if they are turned in the wrong direction.
-

Only turn the fastening bolts in the correct direction of rotation for opening and closing.

-

Turning the fastening bolts carefully ensures that the correct direction of rotation is maintained. The other direction of rotation can be
checked using resistance.

5. Disconnect connection on the air cleaner cover. To do this, turn the fastening bolts through 180 degrees and pull them out. Then pull off the

intake manifold.

Installing cowl for throttle housing (intake manifold)

ATTENTION:

Risk of damaging the fastening bolts.

-

The fastening bolts will break if they are turned in the wrong direction.
-

Only turn the fastening bolts in the correct direction of rotation for opening and closing.

-

Turning the fastening bolts carefully ensures that the correct direction of rotation is maintained. The other direction of rotation can be checked
using resistance.

1. Fit intake manifold and air cleaner cover. To do this, insert fastening bolts and turn them through 180° to secure them.
2. Insert breather hose -arrow A- until the locking tabs -arrows Bare felt to engage.