porsche Workshop Repair Guides

Porsche Workshop Service and Repair Manuals

Procedures|Page 5557 > < Procedures|Page 5555
Page 10
background image

30. Push connector onto DME control module and fasten ground straps.

30.1. Fit ground strap together with the twist lock on the threaded bolt -Arrow A- bolt and screw down with the fastening nut -2-. Tightening

torque: 6 ftlb.

30.2. Push connector onto DME control module -Arrow C- and press in the lock -Arrow D- until it is felt to engage.

31. Fasten wire harness in plenum panel on the left.

31.1. Insert line in the clips -Arrow A- and close clips until the locking tabs are felt to engage -Arrow B-.

32. Insert lines for relay carrier in plenum panel E-box.

32.1. Insert connectors -Arrows A-.
32.2. Push plug connection together -Arrows B-.
32.3. Insert rubber sleeve into relay carrier -Arrow C-.

Procedures|Page 5557 > < Procedures|Page 5555