NOTE:  Before connecting the high-pressure -3- and low-pressure lines -4- to the vehicle, remove any refrigerant remaining in the lines by
suction.

3. Connect the high-pressure and low-pressure lines of the air-conditioning recycling system.

3.1. Let the engine run for a short while with the air-conditioning on, then connect the high-pressure and low-pressure lines of the air-conditioning

unit.

3.2. Open the valves of the high-pressure and low-pressure lines.

NOTE:
-

In the case of service units with transparent oil separator, read and take note of the oil level before removing the refrigerant.

-

Do not carry out this step with empty air-conditioning systems (pressure gauge approx. 0 bar), otherwise air will get into the refrigerant bottle.

-

In the case of cold vehicles, it may be necessary to repeat the suction procedure until all refrigerant has been removed from the
air-conditioning system. This step is carried out automatically with some units.

4. Remove refrigerant by suction.

4.1. Wait for approx. 2 minutes after the service unit has switched itself off. If the pressure gauge reading rises above 0 bar, repeat the suction

process.

NOTE:
-

In the case of service units with transparent oil separator, read and take note of the oil level before removing the refrigerant.

-

Do not carry out this step with empty air-conditioning systems (pressure gauge approx. 0 bar), otherwise air will get into the refrigerant bottle.

-

In the case of cold vehicles, it may be necessary to repeat the suction procedure until all refrigerant has been removed from the
air-conditioning system. This step is carried out automatically with some units.

4.2. Drain the extracted refrigerant oil into a measuring cup on the service unit and determine the volume.

NOTE:
-

The vehicle air-conditioning system is now completely empty. Necessary repairs, such as removing and fitting the dryer, can now be carried
out.

-

The open air-conditioning system should not be left open unnecessarily, but must be closed again as quickly as possible after being opened.

-

If the air-conditioning system has been open for a long time, a new dryer must be fitted.

5. Carry out repairs.

Refrigerant|Capacity Specifications|Page 1621 > < Refrigerant|Capacity Specifications|Page 1619