Valve Clearance: Adjustments
Fig. 13 Valve adjusting sequence.
1.
Connect a remote control starter switch between the starter solenoid and the battery.
2.
Disconnect the coil ignition lead.
3.
Crank over engine until the exhaust valve on cylinder 1 is fully open. (Cylinder 1 is next to the flywheel.) Adjust the intake valve on cylinder No. 3
and the exhaust valve on cylinder No. 4.
4.