Distributor: Pressure, Vacuum and Temperature Specifications

 

Vacuum Advance

Vacuum Advance

C34

D59

D62

D64

D73 

Note:  On models not

No. 

equipped with

Note:  Identification

 

centrifugal advance

number stamped on

 

mechanism, ignition

distributor housing.

 

timing controlled by

 

ignition control module.

 

   

  

  

  

  

  

  

  

Vacuum to Start

3.1 in Hg

4 in Hg

4.13 in Hg

0.94 in Hg

1.1 in Hg 

Plunger 

    

 

  

  

  

  

  

  

  

Max. Advance @

5.5 deg at 13.31 in

7 deg at 14 in hg ---

9.2 deg at 1.38 in

9 deg at 2.17 in hg 

Vacuum

hg

hg 

    

 

  

  

  

  

  

  

  

Max. Retard @

---

---

7 deg at 9.84 in hg

---

--- 

Vacuum 

    

 

  

  

  

  

  

  

  

Vacuum Advance

Vacuum Advance

J10

RE-021B

RE-028 

Note:  On models not

No. 

equipped with

Note:  Identification

 

centrifugal advance

number stamped on

 

mechanism, ignition

distributor housing.

 

timing controlled by

 

ignition control module.

 

   

  

  

  

  

  

  

  

Vacuum to Start

2.95 in Hg

1.5 in Hg

1.5 in Hg 

Plunger 

    

 

  

  

  

  

  

  

  

Max. Advance @

10 deg at 9.45 in 10 deg at 11.5 in 10 deg at 11 in hg 

Vacuum

hg

hg 

    

 

  

  

  

  

  

  

  

Max. Retard @

---

---

--- 

Vacuum 

    

 

  

  

  

  

  

  

  

Electrical Specifications|Page 1561 > < Electrical Specifications|Page 1559