NOTE:

If an accurate scale is available, weigh the refrigerant cans before and during the charging procedure to be sure the correct amount of
refrigerant is being used.

10.

When system is fully charged, close suction (compound) gauge hand valve and all petcock valves.

11.

Operate system five to ten minutes to allow it to normalize and to determine if system cycles properly.

Charging Procedure with Portable Air Conditioner Service Station J-23500-01

WARNING:

Wear protective goggles when servicing the system.

1.

Fill the cylinder. Refer to Filling Charging Cylinder.

2.

Discharge and evacuate system.

3.

Close low pressure valve on charging station. Fully open left hand refrigerant control valve at base of cylinder and high pressure valve on charging
station. Allow required charge of refrigerant to enter high side of system. Close refrigerant control valve and high pressure valve on charging
station when system is charged.

CAUTION: Do not permit liquid level to drop below zero on cylinder sight glass.
4.

Close manifold gauges after completion of charging, and check high and low pressures and system operation.

CAUTION: READ GAUGES WITH HIGH AND LOW PRESSURE VALVES ON CHARGING STATION CLOSED. THE LOW PRESSURE

GAUGE COULD BE DAMAGED IF BOTH HIGH AND LOW PRESSURE VALVES OF MANIFOLD ARE OPENED. HIGH
PRESSURE DEVELOPED IN DISCHARGE SIDE (HIGH SIDE) OF COMPRESSOR WOULD DAMAGE THE GAUGE.

5.

Close all valves on charging station and close refrigerant drum valve when all operations are completed.

6.

On Alliance models, after completing operational checks, back-seat the suction and discharge service valves to their normal operating position by
turning them fully counterclockwise.

7.

Disconnect the high and low pressure charging hoses from compressor with care. (A small amount of refrigerant remaining in the hoses will
escape.) Place the charging hoses on hose back on the charging station to keep air and dirt out of them.

8.

Open the valve at the top of the station charging cylinder to remove any remaining refrigerant.

NOTE:

The charging cylinder is not designed to store refrigerant

9.

Install caps on Alliance compressor service valves when service is completed.

FILING INSTRUCTIONS

File this I.S. Note in your M.R. 171 binder.