saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 3940 > < Diagram Information and Instructions|Page 3938
Page 2
background image

Symbol "o - o" indicates that continuity exists between two points or terminals. For example, when a switch position is at "3", continuity exists among
terminals 1, 3 and 6, as shown in table below.

HOW TO DETERMINE AN OPEN CIRCUIT

WITH VOLTMETER:

An open circuit is determined by measuring the voltage between respective connectors and ground using a voltmeter, starting with the connector closest
to power supply. The power supply must be turned ON so that current flows in the circuit. If voltage is not present between a particular connector and
ground, the circuit between that connector and previous connector is open.

Diagram Information and Instructions|Page 3940 > < Diagram Information and Instructions|Page 3938