saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Air Flow Meter/Sensor|Specifications|Page 2070 > < Air Flow Meter/Sensor|Specifications|Page 2068
Page 2
background image

When airflow increases, higher voltage is required to keep the temperature difference constant.

The necessary voltage is converted to ground pulses, the frequency of which increases with the airmass flow.

The mass air flow sensor is grounded in grounding point G7 and power is supplied from the main relay. Note that the control module has a pull-up to 5 V
on control module input pin 29(B) and that the mass air flow sensor pulses to ground.

When the ignition is switched "ON", the main relay pulls and B+ is supplied to mass air flow sensor pin 3. Current passes RT and the low-ohm heat

Air Flow Meter/Sensor|Specifications|Page 2070 > < Air Flow Meter/Sensor|Specifications|Page 2068