Activation

The solenoid is governed from pin 26 (B) on TCM using a 300 Hz PWM voltage. Grounding takes place on pin 36 (B) on TCM. The current varies
between 0-1000 mA. The solenoid is open when current is not applied. 0 A = high oil pressure 1000 mA = low oil pressure.