saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Body - False Power Window Pinch Protection Activation|Page 1078 > < Body - False Power Window Pinch Protection Activation|Page 1076
Page 3
background image

counts.

1.d. Calculate the difference between the actual upper stop position and the programmed actual stop position by taking the values from pos 1 c
"Programmed upper stop" minus "Window position," e.g. 1168 - 1151 = 17.

If the value is higher than 15, change the window lift's electric motor and then program.

2. If the fault remains, carry out checking and fault diagnosis M03-M04 refer to that procedure.

If the fault has been rectified, then no additional steps are necessary.

Note

If the door control module has been replaced and is M04- then the window lift must be from M04-. If the window lift has been replaced and is M04- then
the door control module must be from M04-. To distinguish the window lift from M03 and M04-, check the colour of the pulley behind the window lift
motor.

M03= White

M04= Light brown/beige

Check the above in order to avoid the pinch protection incorrectly deploying.

3. If the problem remains following the above fault diagnosis, then the pinch protection can be deactivated using Tech 2 (version 127.000 or later) under
the menu entitled Fault diagnosis - Model year 2003 - Saab 9-3 Sport (9440) - All - Service - Activate/Deactivate pinch protection.

Procedure M04

Procedure M04-

Note

This deactivation means that the "Express up" function is deactivated.

1. Check if the window's actual position corresponds with the programmed position.

1.a. Do not program.

1.b. Raise the window using "Express Up."

If this is not possible, temporarily disconnect the pinch protection so that the window can be closed. The ignition should be in the ON position.
Hold down the disconnect button for the rear window lifts in the driver door (the button must be depressed the entire time the window is closing).
Close the applicable window. The next time the window lift is used, the pinch protection will be active again.

1.c. Use Tech2 and check that the read values show that the window is closed. Body - Power Windows - option Driver/Pass door - Read Values.
Select using operation button - advanced operation - select group. Read in menu Window position xxx counts - Window, programmed upper stop xxx
counts.

1.d. Calculate the difference between the actual upper stop position and the programmed actual stop position by taking the values from pos 1 c
"Programmed upper stop" minus "Window position," e.g. 1168 - 1151 = 17.

If the value is higher than 15, change the window lift's electric motor and then program.

4D, M04: If the fault remains, proceed to step 2.

4D/5D M05-M06: If the fault remains, proceed to step 2.

4D/5D M07-: If the fault remains proceed to step 3.

CV M04-06: If the fault remains, proceed to step 2.

CV M07-: If the fault remains, proceed to step 3.

If the fault is rectified then no additional steps are necessary.

Body - False Power Window Pinch Protection Activation|Page 1078 > < Body - False Power Window Pinch Protection Activation|Page 1076