Control Module: Description and Operation
5-Speed, FA 57

TCM, FA 57 (502a)

Main use

Controlling shifting points, system pressure and engagement of lock up.

Type

Microprocessor controlled IO device, working memory and one programmable EEPROM read memory.

Power supply, ground and bus communication

The control module is powered on pin 33 (A) with +30 voltage and on pins 31 (A) and 22 (A) with +15 voltage. The module is grounded via pins 32 (A)
and 23 (A) to grounding point G33T. Bus communication (P-bus) takes place on pins 25-26 (A) and 35-36 (A).