saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Motor, Air Distribution Damper (221)|Page 11212 > < Motor, Air Distribution Damper (221)|Page 11210
Page 2
background image

in K42) in a specific order thus operating the motor in short pulses, which explains the name stepping motor. The rotational direction can be changed.

When the stepping motor is stationary, two windings are continuously grounded in order to lock the motor. The stepping motor does not need to be
reconnected to the control module (position sensor). By sending a specific number of ground pulses, the ACC unit knows how far the air distribution
damper has moved.