Air Door Actuator / Motor: Description and Operation
Motor, Air Distribution, Floor (715)

Motor, Air Distribution, Floor (715)

Main function

The stepping motor is connected via a linkage to damper for the floor vent, which is used for both climate zones.

Type

The unipolar stepping motor consists of a rotor (10 poles) and four stator windings. A gearbox transfers the power from the rotor to the lever which
controls the damper.

Connection

The four stepping motor windings receive a common B+ feed from ACC unit pin 40 (K2).

The ACC unit grounds each winding (pin 9, 29, 8 and 28 in K2) in a specific order thus operating the motor in short pulses, which explains the name
stepping motor. The rotational direction can be changed.

Motor, Air Distribution Damper (221)|Page 11213 > < Motor, Air Distribution Damper (221)|Page 11211