saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Diagnostic Aids|Page 5679 > < Diagnostic Aids|Page 5677
Page 2
background image

Pin No. 2(A)-6(A)

The Trionic T8 control module has a 70-pin connector.

The control module is continuously supplied with +30 current on pin 3(A) and 20(A), and will lose its adapted values and stored trouble codes if it loses
power.