OFF = 0V, ON = B+

Winding resistance in solenoid S1 is rated 12-16 Ohm at 20 degree C

Winding resistance in solenoids S2-S5 is rated 11-15 Ohm at 20 degree C

Diagnostics:

In case of a fault in solenoid S1 fault code P0773 will be generated and the transmission will go into limp-home mode

In case of a fault in solenoid S2 fault code P0753 will be generated and the transmission will go into limp-home mode

In case of a fault in solenoid S3 fault code P0758 will be generated and the transmission will go into limp-home mode

In case of a fault in solenoid S4 fault code P0763 will be generated and the transmission will go into limp-home mode

In case of a fault in solenoid S5 fault code P0768 will be generated and the transmission will go into limp-home mode