9-3 Convertible (9400) L4-2.0L Turbo (2.0 HOT) (2003)
When the ignition is turned ON, the control module outputs B+ via a 1 kOhm resistor to the microswitches from pin 17 and 32, and the microswitches
close when the fifth bow is locked and the control module inputs are grounded.
Microswitch, Soft Top Cover Latch
Microswitch, Soft Top Cover Latch
There are microswitches at each of the soft top cover latches that sense when the cover is in lock position and is ready for locking.
Pin 3 on the left microswitch is connected to control module pin 5 and microswitch pin 2 is connected to grounding point G36.
Pin 3 on the right microswitch is connected to control module pin 33 and microswitch pin 2 is connected to grounding point G36.