saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Diagnostic Tool Screen Does Not Go on With ON Button Pressed|Page 4548 > < Diagnostic Tool Screen Does Not Go on With ON Button Pressed|Page 4546
Page 12
background image

-

Turn the ignition switch to the ON position.

-

The CHECK ENGINE lamp should go on when the ignition is turned ON.

Is the function correct?

NO

-

See: No Communication With Motronic/Checking the Motronic Control Module Power Supply 

YES -

See: No Communication With Motronic/Checking the Diagnostic Tool 

Checking the Diagnostic Tool

Checking The Diagnostic Tool

-

Check whether Motronic can be contacted on another Saab 9-3 using the same diagnostic tool.

Is the function correct?

NO

-

Continue with Checking the diagnostic tool

YES -

See: No Communication With Motronic/Rectifying the Lead - I 

Repair the diagnostic tool or change it, if necessary

After performing this procedure See: No Communication With Motronic/Final Check 

Checking the Motronic Control Module Power Supply

Checking the Motronic Control Module Power Supply

Unplug the connector:

-

Control module, Motronic 2.10.3 (505)

Diagnostic Tool Screen Does Not Go on With ON Button Pressed|Page 4548 > < Diagnostic Tool Screen Does Not Go on With ON Button Pressed|Page 4546