background image

^

Refrigerant containers must not be exposed to heating, because the pressure will then increase resulting in the risk of explosion.

1

Remove the ventilation fan as instructed in WIS, see "Body - Automatic Climate Control ACC - Adjustment/replacement - Ventilation fan".

2

Place the air deflector in the bottom of the fan housing so it rests on the radius on the front edge.

! WARNING

Do not drill deeper than 5 mm as the evaporator may be damaged. Leaking refrigerant can cause personal injury if it makes contact with eyes and
skin.

3

Drill a 1.5 mm hole using the air deflector as a template. Drill in the centre of the hole but not deeper than 5 mm as the evaporator may be
damaged.

Note

Use a drill stop.

Screw on the air deflector using the two screws.

4

Fit the ventilation fan as instructed in WIS, see "Body - Automatic Climate Control ACC - Adjustment/replacement - Ventilation fan".

5

Check the function of the fan.

Warranty/Time Information

To resolve a customer complaint for a vehicle in warranty, submit a claim using the following information:

Failed object: 85404
Fault/Reason code: 56
Location code: 09 (US=0)
Warranty Type (US): 01
Repair/Action code: 10
Labor operation (US): 85404
Time: 0.6 hrs.
(CA: D1322)

Disclaimer