Defect function. Car windows mist up.

Diagnostic help

Check that the recirculation flap is in the fresh-air position when the recirculation button is not pushed in so that the recirculation motor is electrically
reversed.

Diagnostic procedure

1. Checking control voltage to recirculation flap motor
-

Turn the ignition key to the ON position.

-

Unplug the connector: Motor, air recirculation flap: (38).

-

Connect test lamp 86 11 857 between the pins 1 and 2 in the female connector.

-

Turn the air recirculation on and off repeatedly.

-

The red and green LED on the test lamp should go on alternately as air recirculation is turned on and oft.

Tests OK?
YES

-

Replace : Motor, air recirculation flap.