saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Refrigerant|Capacity Specifications|Page 1654 > < Refrigerant|Capacity Specifications|Page 1652
Page 1
background image

Refrigerant: Service and Repair

Filling and draining refrigerant with Robinair Smart Cart 10324 Robinair 17234

WARNING
Read the following safety rules before beginning work on the A/C system:

-

Use protective goggles and tight-fitting gloves since there is a risk of corrosive injuries and frostbite.

-

If there is skin contact with the refrigerant, rinse the affected area with cold water and treat the injury as you would a burn injury.

-

If refrigerant should get into the eyes, rinse with plenty of running water for at least 10 minutes.

-

There must be no uncontrolled release of refrigerant into the atmosphere. If refrigerant should escape in the building, open and air out
before continuing work.

-

Gases formed when the refrigerant is heated are harmful to personal health and can have a serious detrimental effect on the lungs.

-

Smoking and open flames are not allowed when handling refrigerant.

-

Refrigerant containers must not be exposed to heat as the pressure will increase, resulting in an explosion hazard.

The following text describes the use of the special equipment designed for draining and filling refrigerant R134a.
For information regarding the equipment itself, refer to the manufacturer's manuals.
Remember to drain the compressor oil from draining stations at regular intervals (every fourth draining is adequate).

IMPORTANT:  Draining and filling stations for refrigerant R134a must not for any reason be used for refrigerant R12, or vice versa.

Even small amounts of the wrong refrigerant or wrong compressor oil cause chemical reactions which will eventually damage the equipment and also the
car's A/C system.

Snap-on couplings

Special snap-on couplings are used to connect the draining and filling stations hoses to the A/C system service connections. The snap-on couplings are of
the Schrader valve type and connection is accomplished in two steps:

1. Press the snap-on coupling on the service connection.
2. Turn in the knob clockwise so that the valve is opened and the refrigerant can pass through the connection.

When the snap-on couplings are disconnected, first turn the knob (2) counter-clockwise to close the valve. Then remove the snap-on coupling by
pressing the spring-loaded catch (3) so that the locking sleeve (4) can be pulled up.

When the catch is pressed in, a hissing sound will be heard as the catch also serves to evacuate any refrigerant trapped in the snap-on coupling. The
connections on the lowpressure and high-pressure side are of differing size to eliminate the risk for any mix-ups.

Checking pressure with Robinair 10324 Smart Cart

Refrigerant|Capacity Specifications|Page 1654 > < Refrigerant|Capacity Specifications|Page 1652