Front Oxygen Sensor (B235R, B205L/R)|Page 2895 > < Front Oxygen Sensor (B235R, B205L/R)|Page 2893
Page 2
background image

3. Cut the cable tie and pull out the cable.
4. Raise the car.
5. Pull down the cable and remove the oxygen sensor.

IMPORTANT
The leads must not be twisted. The oxygen sensor is highly sensitive to knocks and blows and must be handled with care.

To fit

1. Coat the oxygen sensor's threads with Molycote 1000 (30 20 971) to prevent binding.

IMPORTANT
The oxygen sensor is sensitive to knocks and blows and must be handled with care. It is important to ensure that the connection between it and the
nipple is gastight. Chemicals such as contact spray and grease must not come into contact with the oxygen sensor connectors.