Air Door Actuator / Motor: Description and Operation

Motor, Air Distribution, Defroster (714)

Motor, Air Distribution, Defroster (714)

Location

Motor, air distribution, defroster (714)

Main task

The stepping motor is connected via linkage and controls the defroster damper which is used for both climate zones.

Type

The unipolar stepping motor consists of a rotor (10 poles) and four stator windings. A gearbox transfers the power from the rotor to the lever which
controls the damper.