If there is a short to ground, the CHECK message will not be displayed even if the coolant level is low.

The SID unit will not generate a diagnostic trouble code.

Washer Fluid Level Sensor

Washer fluid level sensor

General

The level sensor consists of a magnetic float arm and a sensor mounted in the washer fluid reservoir.

The SID unit sends B+ to the level sensor via pin 21 and the sensor is grounded at grounding point G30. At normal level, the float arm is level with the
switch, the magnet in the float arm closes the circuit and pin 21 of the SID unit is grounded. At low level, the circuit to ground is broken.

The function produces a CHECK message on the SID unit display (70 second delay).

Diagnostics

If the circuit to the washer fluid level sensor is broken, the text message "WASHER FLUID LEVEL LOW" will be shown despite a correct washer fluid
level.

If a short-circuit to ground occurs, the CHECK message will not be shown even if the washer fluid level is low.

The SID unit will not generate a diagnostic trouble code.