Saab Information Display (SID): Specifications
Test Readings, Control Module Connections

Test readings, control module connections

Scope

The readings and instructions for measuring voltage levels on the SID unit.

Remember

-

Note the test conditions and use common sense when assessing the test result.

-

The presented readings are with the ignition ON unless otherwise stated. First check that the control module has a power supply and is grounded.
Then check all sensor inputs and signals from other systems.

-

Finally, check the control module outputs. Remember that the test readings do not indicate whether or not the actuator is in working order.

-

If any reading is not OK, consult the wiring diagram to trace the leads, connectors or components which should be checked more thoroughly.

-

The specified test readings refer to those obtained with a calibrated Fluke 88/97.

-

The test values %(+) and ms(+) indicate the pulse ratio and pulse duration of the signal. A test instrument for measuring pulse ratio and pulse
duration must be used. The (+) sign indicates a positive trigger pulse, TRIG+.