saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Refrigerant|Capacity Specifications|Page 1907 > < Refrigerant|Capacity Specifications|Page 1905
Page 3
background image

1. Connect the blue low-pressure hose with a snap-on coupling to the A/C system lowpressure side.
2. Connect the red high-pressure hose with a snap-on coupling to the A/C system highpressure side.
3. Open the valves on both snap-on couplings by turning in the knobs.
4. Connect the yellow hose from the pressure gauge stand middle outlet to the draining station.
5. Open the valves for the blue low-pressure hose, the red high-pressure hose and the yellow hose on the pressure gauge unit middle outlet.
6. On the draining station container, open the blue valve ("Liquid") for liquid refrigerant and the red valve ("Gas") for gaseous refrigerant.
7. Start the draining station. The draining station will stop automatically when draining is completed.
8. Close the valves for the blue low-pressure hose, the red high-pressure hose and the yellow hose on the pressure gauge stand middle outlet.
9. Disconnect the yellow hose from the draining station. The draining is now completed and service of the A/C system can start.

Vacuum Pumping And Filling Of Refrigerant

Refrigerant|Capacity Specifications|Page 1907 > < Refrigerant|Capacity Specifications|Page 1905