saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

System Overview|Page 8730 > < System Overview|Page 8728
Page 29
background image

Calculations

The SID unit calculates the ratio between DIST, ARRIV and SPD. To carry out these calculations, the value in DIST must be greater than 0.
If an arrival time is then programmed into ARRIV the SID unit will show the calculated average speed, or if a desired average speed is programmed in
SPD, the SID unit will show the estimated arrival time in ARRIV.
If the calculation is made when the car is running, the calculated value is replaced by the correct figure after 10 seconds. If the calculation is made with
the car stationary, the calculated value is replaced by the correct figure as soon as the car is driven.

ALARM (Time Alarm)

The alarm function is performed after the current time is set on the SID unit clock, after which the alarm time can be programmed.
When the alarm is triggered (activated), the text "ALARM" flashes on the SID unit. An acoustic signal is heard at the same time.
The alarm sounds and flashes for 1 minute or until turned off by one of the SID unit buttons.

SPD W (Speed Warning)

Speed warning uses information on:

-

Speed, unit km/h, mph (bus information from MIU).

-

Programmed speed for warning

The speed warning can be programmed between 0 and 250 km/h (0-155 mph). If the car exceeds the programmed speed, an acoustic signal is heard
every 3 seconds and the text "SPDW" flashes on the display at a frequency of 1 Hz (once a second).

Speed warning, ME

On the ME market, all cars are programmed with a speed warning which is activated when car speed exceeds 120 km/h. This function applies to both
SID 1 and SID 2. For SID 2, this means that the normal SPD W (speed warning) can only be programmed up to 120 km/h.
The function can be programmed ON/OFF using the diagnostic too

Check Messages

System Overview|Page 8730 > < System Overview|Page 8728