Air Door Actuator / Motor: Description and Operation
Stepping Motor, Air-Mixing Damper, ACC

Stepping Motor, Air-mixing Damper

The stepping motor has two windings. A voltage is applied to the windings in special sequence in short pulses. This causes the motor to move in short
steps, hence its name. The rotational direction can be changed. When the stepping motor is stationary, both windings are continuously energised in order
to lock the motor. The stepping motor does not need to be reconnected to the control module (position sensor). By sending a definite number of pulses,
the control module always knows how far the damper has moved. The condition is that the control module has calibrated itself by turning the damper to
the respective end positions so that the control module knows the position of the damper.

Calibration is performed by simultaneously pressing the AUTO and OFF buttons. Calibration must be performed if the battery has been