saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

System Overview|Page 13112 > < System Overview|Page 13110
Page 33
background image

Rheostat Level

The SID unit is connected to the rheostat and controls the button lighting in the SID unit. It is also used to calculate the display lighting level.
The buttons are illuminated by 2 bulbs and the display by 4 bulbs, all easily accessible from the rear of the SID unit. When the main light switch is ON,
bus information is sent: RHEOSTAT LEVEL, unit %. The information is used by the ACC, Audio, DICE and MIU to regulate the button and instrument
lighting.

Rheostat level 0 % is sent if:

-

The main light switch is OFF

-

The interior light exceeds a certain level.

The information is used by the ACC, Audio, DICE and MIU which then extinguishes the button and instrument lighting.

Display Lighting Level

System Overview|Page 13112 > < System Overview|Page 13110