saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 4556 > < Initial Inspection and Diagnostic Overview|Page 4554
Page 49
background image

-

The test lamp should light.

Checking the wiring harness.

Jiggle the leads and in-line connectors at several places and in different directions to reveal intermittent breaks and short circuits in the wiring harness.
Observe the multimeter, test lamp or diagnostic tool while doing this.

Is the function correct?

NO

-

See: No Communication With the Trionic T5/Rectifying the Lead - III 

YES -

See: No Communication With the Trionic T5/Final Check 

Checking the Diagnostic Tool

Checking The Diagnostic Tool

-

Check whether Trionic can be contacted on another Saab 9-3 using the same diagnostic tool.

Is the function correct?

NO

-

Continue with Checking the Diagnostic tool

YES -

See: No Communication With the Trionic T5/Rectifying the Lead - I 

Repair the diagnostic tool or change it, if necessary.

After performing this procedure See: No Communication With the Trionic T5/Final Check 

Rectifying the Lead - I

Rectifying The Lead

Unplug the connector:

Initial Inspection and Diagnostic Overview|Page 4556 > < Initial Inspection and Diagnostic Overview|Page 4554