Page 6
background image

The engagement time depends on outside temperature.
At 5 °C, the time is 4 minutes and at lower temperatures the time increases to max 10 minutes and that is achieved at an outside temperature lower than 
-10 °C.

NOTE: Experience shows that half of all ACC control modules that claims were made for during the warranty period were free of defects but
programmed by the user. It is therefore very important to explain the function to the customer.

Control Panel Inputs, Outputs, Power Supply & Grounds, MCC

Control Panel Inputs

-

Power supply +54

-

Ground

-

Parking heater 

-

Instrument lighting heater controls

-

Instrument lighting switches, electrically heated rear window and door mirrors

Control panel outputs