1

Hold the ohmmeter leads in contact with each other and adjust the instrument until a reading of 0 ohm is obtained.

2

Disconnect the load and the negative battery cable.

3

Connect one of the ohmmeter leads to the pin of the short-circuited cable.

4

Connect the other lead to a good grounding point on the car.

5

Jiggle the relevant wiring harness while observing the ohmmeter.
^

If the ohmmeter shows infinite resistance, there is no short circuit.

^

On the other hand, if it shows low resistance or none at all, this indicates that the cable is short-circuited to ground.