saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Refrigerant|Capacity Specifications|Page 2006 > < Refrigerant|Capacity Specifications|Page 2004
Page 3
background image

1

Connect the blue low-pressure hose with a snap-on coupling to the A/C system low-pressure side.

2

Connect the red high-pressure hose with a snap-on coupling to the A/C system high-pressure side.

3

Open the valves on both snap-on couplings by turning in the knobs.

4

Connect the yellow hose from the pressure gauge stand middle outlet to the draining station.

5

Open the valves for the blue low-pressure hose, the red high-pressure hose and the yellow hose on the pressure gauge unit middle outlet.

6

On the draining station container, open the blue valve ("Liquid") for liquid refrigerant and the red valve ("Gas") for gaseous refrigerant.

7

Start the draining station. The draining station will stop automatically when draining is completed.

8

Close the valves for the blue low-pressure hose, the red high-pressure hose and the yellow hose on the pressure gauge stand middle outlet.

9

Disconnect the yellow hose from the draining station. The draining is now completed and service of the A/C system can start.

Vacuum Pumping And Filling Of Refrigerant

Refrigerant|Capacity Specifications|Page 2006 > < Refrigerant|Capacity Specifications|Page 2004