9-3 Viggen Convertible (9400) L4-2.3L Turbo (B235) HO (2001)
-
The radiator fan continues to run for 3 minutes if the coolant temperature is 107°C or above.
-
The radiator fan stops if the coolant temperature is below 107°C.
-
The radiator fan continues to run for 30 seconds if the coolant temperature is 103°C or above.
-
The radiator fan stops if the coolant temperature is below 103°C
30 seconds after ignition OFF:
-
If the radiator fan did not stop when the ignition was turned OFF, it will continue to run for 3 minutes if the coolant temperature is 107°C or
above. After 3 minutes the fan will stop. If the coolant temperature is below 107°C the fan will stop.
-
If the radiator fan stopped when the ignition was turned OFF, it will start and run for 3 minutes if the coolant temperature is 107°C or above.
After 3 minutes the fan will stop. If the coolant temperature is between 103°C and 107°C, the fan will start and run for 30 seconds. If the coolant
temperature is below 103°C the fan will stop.
60 seconds after ignition OFF:
Only applicable if the coolant temperature was between 103°C and 107°C 30 seconds after ignition OFF.
-
The radiator fan continues to run for 3 minutes if the coolant temperature is 107°C or above.
-
The radiator fan stops if the coolant temperature is below 107°C.
Immediately after ignition OFF the fan starts and runs at low speed for 2 seconds. At the end of this time the same logic applies as when the radiator
fan runs at low speed when the ignition is turned from ON to OFF.