saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Electrical - Battery Maintenance|Page 5925 > < Electrical - Battery Maintenance|Page 5923
Page 5
background image

1.

Vehicle (Dealer Reference No)

Used by the dealer as necessary (stock no., coordinate, etc.) to help identify and locate the car and respective key.

2.

VIN

The car's vehicle identification number as specified at the factory.

Factory

This section is completed at the factory after the battery has been approved for delivery.

3.

Battery OK Date

The date the battery was checked and approved for delivery at the factory (Customer Care).

4.

Code

Battery test code according to battery test at factory.

5.

Battery type - CCA (SAE)

The marked box specifies the size of the factory-fitted battery in CCA ("Cold Cranking Amps") according to SAE standard.

Dealer

The result of every battery test carried out while the dealer is responsible for battery maintenance, i.e. up until the day the car is delivered to the
customer is registered in this section.

12 Date

The date the battery is checked is noted here. Normally, the battery is checked monthly. Demonstration cars in showrooms, etc., are tested weekly.
This applies if the battery has not been disconnected.

13 Code

The test code obtained from Battery Analyzer 311 is noted here.

Note

The test code is required for possible warranty claims on the battery.

14 Message - Action

The test message given by Battery Analyzer 311 is noted here together with any measures taken where appropriate.

Note

If charging is needed - Check the battery and update the battery card after charging.

Monitoring system

Besides Battery Analyzer 311 and the battery card, each dealer should have a system for keeping track of cars requiring test or recharging
respectively. We recommend a simple PC register program or a binder system where cars in storage, showroom cars and cars being made ready for
delivery can be identified.

Test procedure

Select the relevant alternative in each menu with the arrow buttons.

Use the <-- button to confirm a selection. The selections that are made now will remain as default selections the next time the analyzer is turned
on.

1.

Check the acid level in the battery and top up if necessary (especially on warm markets). If the battery has been used for a time with low acid level,
it should be charged after topping up before the battery test is carried out.

Note

Electrical - Battery Maintenance|Page 5925 > < Electrical - Battery Maintenance|Page 5923