9-3 Viggen Coupe (9400) L4-2.3L Turbo (B235) HO (1999)
-
The test lamp should light up.
Tests OK?
YES
-
Proceed to step 4.
NO
-
Repair the lead between the ventilation fan switch, pin 2 and fuse 3.
-
Proceed to step 14.
4. Checking fan grounding connection
-
Unplug the connector: Motor, ventilation fan: (36)
-
Connect test lamp 86 11 857 between B+ and pin 5 on the female connector.
-
The test lamp should light up.