9-3 Viggen Coupe (9400) L4-2.3L Turbo (B235) HO (1999)
Manifold Absolute Pressure Sensor: Description and Operation
Manifold Absolute Pressure Sensor - Trionic T5
V
Voltage at 25 kPa (-0.75 bar)
approx. 0.48
50 kPa (-0.50 bar)
approx. 0.95
100 kPa (±0 bar)
approx. 1.9
125 kPa (0.25 bar)
approx. 2.4
150 kPa (0.50 bar)
approx. 2.8
175 kPa (0.75 bar)
approx. 3.3
Pressure given in kPa is absolute pressure, i.e. 100 kPa corresponds with atmospheric pressure. Somewhat lower voltage readings may be obtained when
testing the pressure sensor with a pressure-vacuum pump at high altitudes. Power supply 5 V