saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Motor, Air Distribution, Defroster (714)|Page 13006 > < Motor, Air Distribution, Defroster (714)|Page 13004
Page 15
background image

When the stepping motor is stationary the two windings are continuously ground to lock the motor. The stepping motor does not need to be reconnected
to the control module (position sensor), but by sending out a specific number of ground pulses the ACC unit always knows how far the air distribution
flap has moved.

Motor, Air Recirculation Flap (38), ACC

Motor, Air Recirculation Flap (38), ACC

Location

Motor, air recirculation flap (38).

Main task

The motor is connected with linkage which controls the air recirculation flap. The flap regulates air flow to the fan so that the air is retrieved from
outside the cabin or from inside the cabin; there is no intermediate setting.

Motor, Air Distribution, Defroster (714)|Page 13006 > < Motor, Air Distribution, Defroster (714)|Page 13004