4. Select body system and navigate to TWICE with the diagnostic tool. Do not press ENTER.
5. Hold the accompanying transponder above the hole in the antenna unit.
6. Press ENTER on the diagnostic tool.
7. Select Programming
8. Select Spare Part Programming
9. Perform spare part programming. Select the alternatives applicable to the car in question.

10. Upon completion of spare part programming, select "Programming of transponders and remote controls". Press ENTER. Press NO when asked

"Do you wish to exit".

11. Hold the accompanying transponder above the hole in the antenna unit. The seat-belt warning lamp will blink to show that the transponder code

was understood by TWICE. Press OK.

12. Turn off the ignition and restart from step 3 if the seat belt warning lamp does not flash.
13. Follow the instructions in the diagnostic tool, with the following exceptions:

At the first time with step three in Tech 2, refit the antenna unit and refit the same key.

NOTE:  The antenna unit should not be fitted at low temperatures due to the risk of crack formation.

14. Follow the instructions in the diagnostic tool:

Tech 2

1. Look at the 'FASTEN SEATBELT' lamp
2. Press the remote control unlock button once per second until the 'FASTEN SEATBELT' lamp blinks once. More than 8 presses on the button may

be necessary.

3. Remove the key from the ignition switch and fit the next key.
4. Turn the key to the 'ON' position.
5. Repeat steps 1 and 2.

Additional keys and remote controls are programmed in following points 3-5.

Press 'OK' once all keys and remote controls are programmed.

1. Once all keys are programmed, select "Immobilization".
2. Perform immobilization programming.
3. Clear DTCs in TWICE.
4. Clear DTCs in the engine management system.
5. Discard the accompanying transponder.