saab Workshop Repair Guides

Saab Workshop Service and Repair Manuals

Main Components|Page 9600 > < Main Components|Page 9598
Page 20
background image

General

The SID receives information from the filament monitor concerning the functionality of the headlamps.

The SID sends B+ to the filament monitor via pin 23. If a headlamp bulb is faulty, the filament monitor output will be grounded.

The SID uses the information to generate a CHECK message(3 seconds delay).

Diagnostics

If a short-circuit to ground occurs in the filament monitor circuit, the CHECK message for a faulty lamp will be shown even though the lamp is OK.

In the event of an open circuit, the CHECK message will not be shown even if one of the lamps is faulty.

Function Keys

Function Keys

The SID comes in two versions, SID 1 and SID 2.

SID 1

The following function keys are used on SID1:

Main Components|Page 9600 > < Main Components|Page 9598